Product Introduction
SSR Solid State Relay Usage Precautions
1. Load Derating: Use at 60%-70% of the rated current. Overvoltage and overcurrent operation are strictly prohibited.
2. Heat Dissipation Installation: 25A and above models must be equipped with a heat sink. Apply thermal grease to the contact surfaces.
3. Load Protection: When controlling inductive/capacitive loads, an RC snubber circuit or varistor must be installed.
4. Proper Wiring: Distinguish between input and output according to the markings. Ensure terminals are tightened securely to prevent overheating from loose connections.
5. Environmental Limitations: Avoid use in humid, highly corrosive, strongly electromagnetically interfered, or excessively hot environments.
6. Live Safety: Disassembly and repair while the circuit is energized are strictly prohibited. Immediately disconnect power and replace the faulty relay.
Specifications and Specifications:
| Parameter | Specification |
|---|---|
| Product Model | SSR-70DA |
| Control Method | DC-AC |
| Input Control Voltage | 3V~32V DC |
| Input Control Current | 5~20mA |
| Load Voltage Range | 24V~380V AC |
| Rated Load Current | 70A |
| Output Voltage Drop | ≤1.5V |
| Off-State Leakage Current | ≤1mA |
| Operating Frequency | 50/60Hz |
| Insulation Withstand Voltage | ≥2500V AC (Input - Output) |
| Insulation Resistance | ≥1000MΩ |
| Operating Ambient Temperature | -30℃ ~ +80℃ |
| Installation Method | Panel Mount |
| Housing Material | Flame Retardant Engineering Plastic |
| Cooling Method | Natural Cooling (Recommended with a dedicated heatsink) |
| Contact Type | Normally Open (Contactless Semiconductor Switch) |












Hot Tags: ssr solid-state relay 75a, China, suppliers, manufacturers, customized, wholesale, cheap, discount, bulk, in stock, free sample